UL / IEC certification status

  • R32 : FIS5000 series / IEC60335-2-40 Ed.7 ANNEX LL
    Passed
  • R290 : FIS5000 series / IEC60335-2-40 Ed.7 ANNEX LL
    Passed
  • R32 : FIS6084 series, FIS5084 series / UL60335-2-40 Ed.4 ANNEX LL
    Authenticated
  • R454B : FIS5085 series / UL60335-2-40 Ed.4 ANNEX LL
    Authenticated

sensor modules for refrigerant leak detection specification.

 FIS5084-01NCFIS5084-01C1
Image
FIS5084-01NC
FIS5084-01C1
Appearancewithout casewith case
Gas SensorSB type semiconductor gas sensor
Taget GasR32
Gas Concentration Range1.000~ 10,000ppm
Alarm ConcentrationR32 5,000ppm
Alarm OutputOpen collector
Operating and Short Temperature range-25~60℃(without dew condensation)
Power Supply5.0V DC± 5%
Average Power Concentration40mA
Dustproof & WaterproofMoisture-proof paint
Other Target Gasses※R290,R454B,R1234yf,etc

※Specification to be changed as per type of refrigerant gas.

Product Features

The refrigerant leak detection modules use semiconductor gas sensors. The sensors currently satisfy the performance standards established by the Japan Refrigeration and Air Conditioning Industry Association [JRA4068:2021 (Performance 3)], as well as the internationally recognized IEC60335-2-40 Edition 7.0 Moreover, we are in the process of developing products that meet the UL60335-2-40 Edition 4.0 standards.

  1. Target Gases
    The sensors can detect A2L refrigerants including R32, R454B, and others, as well as A3 refrigerants such as R290 and R600. The refrigerant sensors provide linear responses to refrigerant concentrations of 1,000 – 10,000 ppm, and also feature temperature compensation functions. The modules maintain their sensitivity within an operating temperature range of -25℃ to +60℃. Sensitivity of the semiconductor gas sensors to various gases is presented in this log-log graph, which shows changes in sensor resistance (RS) values at different gas concentrations. As shown in the graph, sensor resistance decreases as refrigerant gas concentration increases.
  2. Superior Durability
    Semiconductor gas sensors make calibration unnecessary, and these modules can be used for up to 15 years without replacing the sensors. These sensors can accurately detect refrigerants even following hydrogen and methane gas exposure tests.
    Internal filters
  3. Internal filters minimize the effects of gas interference
    Internal filters reduce the effects caused by interfering gases, such as ethyl alcohol and silicon gas, which are present in the ambient environment where the sensors are used. This minimizes gas interference effects and allows for selective detection of refrigerants such as Freon replacements (HFCs).
    Internal filters
    Internal filters
  4. Easy Integration
    The modules are pre-adjusted using a target gas (R32), so they are ready to be installed in other products without requiring time-consuming gas calibration. These small, lightweight modules produce output signals that are easy to extract, allowing for convenient integration into various devices. They interface with air conditioning units via a connector, which provides superior ease of maintenance and makes regular replacement convenient.
  5. Water Resistant Design
    We offer modules with water resistant coating on substrate and passed environmental durability test under high humidity.These modules can be installed in refrigeration and air conditioning systems used in environments where condensation is likely, such as outdoor units and refrigerators
    Shousing for water resistant
    Module with moisture-proof case
Nissha FIS is also developing a sensor that complies with UL standards.

Nissha FIS is also developing a sensor that complies with UL standards.

Click here

Introducing gas sensor application examples in various fields

Product category

  • Gas sensor
  • Gas sensor module
  • Gas detecting device
  • Gas measuring deivce

productsLearn more

Inquiry

Inquiry

Please feel free to contact us

CONTACT
Download

Download

Download our catalog here!

DOWNLOAD